Initial experience of a self‐expanding transcatheter aortic valve with an outer pericardial wrap: The United Kingdom and Ireland Implanters' registry
Citations Over TimeTop 19% of 2019 papers
Abstract
Abstract Objectives The United Kingdom and Ireland Implanters' registry is a multicenter registry which reports on real‐world experience with new transcatheter heart valves. Background The Evolut PRO (Medtronic, Minneapolis, MN) transcatheter aortic valve is a self‐expanding transcatheter aortic valve with an outer pericardial wrap, designed to minimize paravalvular regurgitation. Methods Between July 2017 and December 2018, clinical, procedural, and 30‐day outcome data were prospectively collected from all patients receiving the Evolut PRO valve across nine participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium‐2 (VARC‐2)‐defined endpoint of device success. The primary safety outcome was the VARC‐2‐defined composite endpoint of early safety at 30 days. Results A total of 317 patients underwent implantation. Mean age was 81.8 ± 6.4 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.5 ± 1.8%. Iliofemoral access was used in 99.1% of patients. Device success was 91.2%. Mean gradient was 7.6 ± 4.7 mmHg and effective orifice area 1.9 ± 0.7 cm 2 . The incidence of moderate paravalvular regurgitation was 1.7% and there was no severe paravalvular regurgitation. A new permanent pacemaker was implanted in 17.8% of patients without a pacemaker at baseline. Early safety was demonstrated in 92.7%. At 30 days, all‐cause mortality was 0.6%, stroke 3.8%, and major vascular complication 2.8%. Conclusions Real‐world experience of the Evolut PRO transcatheter aortic valve demonstrated favorable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation.
Related Papers
- → Doubly committed Subarterial Ventricular Septal defect repair: An experience of 51 cases(2017)6 cited
- → Cineaortography in the assessment of aortic regurgitation: a comparison of different catheter types(1986)4 cited
- → CRT-700.12 3D Printing and Computer Modeling to Predict Paravalvular Leak in Transcatheter Aortic Valve Replacement(2018)1 cited
- Noninvasive evaluation of congenial aortic valve disease by transthoracic echocardiography(2011)
- → Transcatheter aortic valve replacement valve in transcatheter aortic valve replacement valve for severe periprosthetic regurgitation(2020)