Multi‐gradient‐echo myelin water fraction imaging: Comparison to the multi‐echo‐spin‐echo technique
Magnetic Resonance in Medicine2017Vol. 79(3), pp. 1439–1446
Citations Over TimeTop 10% of 2017 papers
Abstract
Overall, we observed excellent agreement between the two techniques. The small positive bias of the MGRE-MWF is thought to be a consequence of its potentially reduced sensitivity to water exchange effects, compared to the MESE-MWF. This work suggests that with careful correction for the effects of field inhomogeneities, MGRE-MWF imaging is a promising alternative to the MESE approach. Magn Reson Med 79:1439-1446, 2018. © 2017 International Society for Magnetic Resonance in Medicine.