Free‐breathing simultaneous T1, T2, and T2∗ quantification in the myocardium
Citations Over TimeTop 12% of 2021 papers
Abstract
Simulations confirmed accurate fitting with the 5-parameter model. Phantom measurements showed good agreement with the reference methods in the relevant range for in vivo measurements. Compared to single-parameter methods comparable accuracy was achieved. SATURN produced in vivo parameter maps that were visually comparable to single-parameter methods. No significant difference between T1 , T2 , and T2∗ times acquired with SATURN and single-parameter methods was shown in quantitative measurements (SATURN T1=1573±86ms , T2=33.2±3.6ms , T2∗=25.3±6.1ms ; conventional methods: T1=1544±107ms , T2=33.2±3.6ms , T2∗=23.8±5.5ms ; P>.2 ) CONCLUSION: SATURN enables simultaneous quantification of T1 , T2 , and T2∗ in the myocardium for comprehensive tissue characterization with co-registered maps, in a single scan with good agreement to single-parameter methods.