Branched Perfluorooctane Sulfonate Isomer Quantification and Characterization in Blood Serum Samples by HPLC/ESI-MS(/MS)
Citations Over TimeTop 10% of 2009 papers
Abstract
Perfluorooctane sulfonate (PFOS) is a global contaminant and is currently among the most prominent contaminants in human blood and wildlife samples. Although "total PFOS" (SigmaPFOS) analytical methods continue to be the most commonly used for quantification, recent analytical method developments have made it possible to resolve the various isomers of PFOS by HPLC-MS/MS. Characterized technical PFOS standards (i.e., containing a mixture of PFOS isomers) are now available that enable isomer specific quantification of PFOS, however the advantages of such an analysis have notyet been examined systematically. Herein, PFOS isomers have been individually quantified for the first time in real samples and the results are compared to a traditional SigmaPFOS method; the influence of analytical standards and isomer specific electrospray and MS/ MS behavior were also investigated. The two human serum standard reference materials chosen for analysis contained dramaticallydifferent PFOS isomer profiles (approximately 30-50% total branched isomers) emphasizing that isomer patterns should not be ignored and may provide useful information on exposure sources (i.e., direct exposure to PFOS vs indirect exposure from PFOS-precursors). Depending on the sample and the particular MS/MS transition chosen for SigmaPFOS analysis (i.e., 499-->80 or 499-->99), SigmaPFOS concentrations may be over- or underestimated compared to the isomer specific analysis. Differences in the extent of in-source fragmentation and MS/MS dissociation contributed to the systematic analytical bias. It was also shown that SigmaPFOS data are prone to interlaboratory variation due to various choices of PFOS standards and instrumental conditions used. In the future, for either SigmaPFOS or isomer specific PFOS analyses, we suggest that accuracy can be maximized and interlaboratory discrepancies minimized by using a common chemically pure technical PFOS standard characterized by 19F NMR.
Related Papers
- → Amino-functionalized UiO-66 as a Novel Adsorbent for Removal of Perfluorooctane Sulfonate from Aqueous Solution(2021)33 cited
- → Study on the generation of perfluorooctane sulfonate from the aqueous film-forming foam(2007)42 cited
- → Highly sensitive and selective detection of perfluorooctane sulfonate based on the Janus Green B resonance light scattering method(2016)29 cited
- → Factors Influencing the Ferric Ion-mediated Photochemical Decomposition of Perfluorooctane Sulfonate (PFOS) in Water(2015)9 cited
- Perfluorooctane Sulfonate (PFOS) in Leather and Products(2010)