Abstract
A simple, sensitive, and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining urinary creatinine was developed and used to evaluate 24 h urine samples collected during an exposure study. Urine (1 microL) was diluted with methanol and then directly applied to LC-MS/MS. Under electrospray ionization (ESI) conditions, the transition molecules of creatinine and creatinine- d3 were observed at m/ z 114 > 44 and m/ z 117 > 47, respectively. The retention time of creatinine was 0.59 min. The linear range was 1-2000 ng/mL, with a detection limit in urine of 1 ng/mL. LC-MS/MS and colorimetric end-point methods were significantly associated ( R2 = 0.8785, p < 0.0001). The LC-MS/MS method to determine creatinine in 24 h urine samples had shorter retention times, was more sensitive, reliable, reproducible, simple, selective, and used a smaller sample size than other LC-MS/MS or commercial methods.
Related Papers
- → Determination of Grayanotoxins from Rhododendron brachycarpum in Dietary Supplements and Homemade Wine by Liquid Chromatography–Quadrupole Time-of-Flight–Mass Spectrometry and Liquid Chromatography–Tandem Mass Spectrometry(2018)8 cited
- → Validation of a liquid chromatography tandem mass spectrometry assay for serum creatinine and comparison with enzymatic and Jaffe methods(2006)36 cited
- → Determination of trenbolone and its metabolite in bovine fluids by liquid chromatography–tandem mass spectrometry(2002)35 cited
- → Liquid chromatography–ion trap tandem mass spectrometry for the characterization of polypeptide antibiotics of the colistin series in commercial samples(2002)30 cited
- → Identification of potassium dehydroandrographolidi succinas and its major metabolites in rat urine by liquid chromatography–tandem mass spectrometry(2011)1 cited