Influence of Surface Heterogeneity on Electrokinetically Driven Microfluidic Mixing
Citations Over TimeTop 1% of 2002 papers
Abstract
Electroosmotic flow in microfluidic systems is limited to the low Reynolds number regime. As a result species mixing in electroosmotic flow systems is inherently diffusion dominated, requiring both a long mixing channel and retention time to attain a homogeneous solution. Recent studies have shown that the introduction of oppositely charged surface heterogeneities to microchannel walls can result in regions of localized flow circulation within the bulk flow. In this study we seek to investigate these circulation regions, through 3D finite-element based numerical simulations, and then use them as a method of enhancing species mixing in a T-shaped micromixer. While all cases of surface heterogeneity are shown to enhance mixing efficiency, greater improvement is found when both the size of the heterogeneous region and the degree of heterogeneity (i.e., the difference between the heterogeneous and homogeneous ζ-potentials) are increased. In some cases the presence of heterogeneous regions is shown to reduce the required mixing channel length by as much as 70%.
Related Papers
- → Experimental and Numerical Investigation of a Novel Spiral Micromixer with Sinusoidal Channel Walls(2021)52 cited
- → Impacts of channel wall twisting on the mixing enhancement of a novel spiral micromixer(2021)48 cited
- → AC electroosmotic micromixer for chemical processing in a microchannel(2006)150 cited
- → Mixing Performance of a Planar Asymmetric Contraction-and-Expansion Micromixer(2022)7 cited
- → A novel passive micromixer with modified asymmetric lateral wall structures(2018)12 cited