The refractive index and electronic gap of water and ice increase with increasing pressure
Citations Over TimeTop 10% of 2014 papers
Abstract
Determining the electronic and dielectric properties of water at high pressure and temperature is an essential prerequisite to understand the physical and chemical properties of aqueous environments under supercritical conditions, for example, in the Earth interior. However, optical measurements of compressed ice and water remain challenging, and it has been common practice to assume that their band gap is inversely correlated with the measured refractive index, consistent with observations reported for hundreds of materials. Here we report ab initio molecular dynamics and electronic structure calculations showing that both the refractive index and the electronic gap of water and ice increase with increasing pressure, at least up to 30 GPa. Subtle electronic effects, related to the nature of interband transitions and band edge localization under pressure, are responsible for this apparently anomalous behaviour.
Related Papers
- → The refractive index of human hemoglobin in the visible range(2011)201 cited
- → High-pressure evolution of the refractive index of MgO up to 140 GPa(2022)9 cited
- → <title>Measuring refractive indices of films on semiconductors by microreflectometry</title>(1990)5 cited
- → Simultaneous determination of thickness and refractive index using Cauchy or Sellmeier formulas by the example of surface plasmon resonance study on ultrathin polysulfone film(2021)3 cited
- → An error analysis of the SYNCANG and SYNCWANG methods for the measurement of film refractive index and thickness(1977)4 cited