Nearly diffraction-limited X-ray focusing with variable-numerical-aperture focusing optical system based on four deformable mirrors
Citations Over TimeTop 10% of 2016 papers
Abstract
Unlike the electrostatic and electromagnetic lenses used in electron microscopy, most X-ray focusing optical systems have fixed optical parameters with constant numerical apertures (NAs). This lack of adaptability has significantly limited application targets. In the research described herein, we developed a variable-NA X-ray focusing system based on four deformable mirrors, two sets of Kirkpatrick-Baez-type focusing mirrors, in order to control the focusing size while keeping the position of the focus unchanged. We applied a mirror deformation procedure using optical/X-ray metrology for offline/online adjustments. We performed a focusing test at a SPring-8 beamline and confirmed that the beam size varied from 108 nm to 560 nm (165 nm to 1434 nm) in the horizontal (vertical) direction by controlling the NA while maintaining diffraction-limited conditions.
Related Papers
- → The ID23-2 structural biology microfocus beamline at the ESRF(2009)205 cited
- → The new small-angle X-ray scattering beamline for materials research at PETRA III: SAXSMAT beamline P62(2023)32 cited
- → Development of a new state-of-the-art beamline optimized for monochromatic single-crystal and powder X-ray diffraction under extreme conditions at the ESRF(2005)141 cited
- → The SESAME materials science beamline for XRD applications(2017)8 cited
- → General method for automatic on-line beamline optimization based on genetic algorithm(2015)10 cited