Thermonuclear ignition in inertial confinement fusion and comparison with magnetic confinement
Citations Over TimeTop 10% of 2010 papers
Abstract
The physics of thermonuclear ignition in inertial confinement fusion (ICF) is presented in the familiar frame of a Lawson-type criterion. The product of the plasma pressure and confinement time Pτ for ICF is cast in terms of measurable parameters and its value is estimated for cryogenic implosions. An overall ignition parameter χ including pressure, confinement time, and temperature is derived to complement the product Pτ. A metric for performance assessment should include both χ and Pτ. The ignition parameter and the product Pτ are compared between inertial and magnetic-confinement fusion. It is found that cryogenic implosions on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] have achieved Pτ∼1.5 atm s comparable to large tokamaks such as the Joint European Torus [P. H. Rebut and B. E. Keen, Fusion Technol. 11, 13 (1987)] where Pτ∼1 atm s. Since OMEGA implosions are relatively cold (T∼2 keV), their overall ignition parameter χ∼0.02–0.03 is ∼5× lower than in JET (χ∼0.13), where the average temperature is about 10 keV.
Related Papers
- → First Liquid Layer Inertial Confinement Fusion Implosions at the National Ignition Facility(2016)67 cited
- → High energy x-ray imager for inertial confinement fusion at the National Ignition Facility(2006)5 cited
- → The National Ignition Facility for inertial confinement fusion(2002)5 cited
- → Fundamental technical characteristics of the experimental thermonuclear system ?Tokamak-3?(1964)4 cited
- → Inertial Confinement Fusion Quarterly Report: April--June 1993. Volume 3, Number 3(1993)