Investigation of background electron emission in the LUX detector
Citations Over TimeTop 10% of 2020 papers
Abstract
Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.
Related Papers
- → Photoionization of Ce3+and Ce3+@C60(2009)13 cited
- → Theoretical treatment of molecular photoionization based on the R-matrix method(2012)1 cited
- → Regularities and irregularities in partial photoionization cross sections of He(2002)16 cited
- → Photoionization effects in streamer discharges(2006)1 cited
- → Application of UV/VUV Free-Electron Lasers to Photoionization Mass Spectroscopy(1988)