Measurement of the decays Λc→Σππ at Belle
Citations Over TimeTop 12% of 2018 papers
Abstract
We report measurements of the branching fractions of the decays ${\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{+}{\ensuremath{\pi}}^{\ensuremath{-}}{\ensuremath{\pi}}^{+}$, ${\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{0}{\ensuremath{\pi}}^{+}{\ensuremath{\pi}}^{0}$ and ${\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{+}{\ensuremath{\pi}}^{0}{\ensuremath{\pi}}^{0}$ relative to the reference channel ${\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}p{K}^{\ensuremath{-}}{\ensuremath{\pi}}^{+}$. The analysis is based on the full data sample collected at and near the $\mathrm{\ensuremath{\Upsilon}}(4S)$ resonance by the Belle detector at the KEKB asymmetric-energy ${e}^{+}{e}^{\ensuremath{-}}$ collider, corresponding to an integrated luminosity of $711\text{ }\text{ }{\mathrm{fb}}^{\ensuremath{-}1}$. We measure $\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{+}{\ensuremath{\pi}}^{\ensuremath{-}}{\ensuremath{\pi}}^{+})/\phantom{\rule{0ex}{0ex}}\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}p{K}^{\ensuremath{-}}{\ensuremath{\pi}}^{+})=0.719\ifmmode\pm\else\textpm\fi{}0.003\ifmmode\pm\else\textpm\fi{}0.024$, $\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{0}{\ensuremath{\pi}}^{+}{\ensuremath{\pi}}^{0})/\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}p{K}^{\ensuremath{-}}{\ensuremath{\pi}}^{+})=0.575\ifmmode\pm\else\textpm\fi{}0.005\ifmmode\pm\else\textpm\fi{}0.036$ and $\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}{\mathrm{\ensuremath{\Sigma}}}^{+}{\ensuremath{\pi}}^{0}{\ensuremath{\pi}}^{0})/\mathcal{B}({\mathrm{\ensuremath{\Lambda}}}_{c}^{+}\ensuremath{\rightarrow}p{K}^{\ensuremath{-}}{\ensuremath{\pi}}^{+})=0.247\ifmmode\pm\else\textpm\fi{}0.006\ifmmode\pm\else\textpm\fi{}0.019$. The listed uncertainties are statistical and systematic, respectively.
Related Papers
- Decay of the $\Lambda(1520)$ to $\Lambda\pi\pi$ via $\Sigma(1385)\pi$(2013)
- Observation of anomalous Y(1S)pi(+)pi(-) and Y(2S)pi(+)pi(-) production near the Y(5S) resonance(2008)
- Study ofe+e- to Lambda anti-Lambda, Lambda anti-Sigma^0,Sigma^0 anti-Sigma^0 using Initial State Radiation with BaBar(2007)