Biomechanical Comparison of Three Internal Fixation Techniques for Stabilizing Posterior Pelvic Ring Disruption: A 3D Finite Element Analysis
Orthopaedic Surgery2019Vol. 11(2), pp. 195–203
Citations Over TimeTop 10% of 2019 papers
Abstract
Based on our results, we believe that the stability of Tile C pelvic fracture fixed with MIAP was similar to that of fractures fixed with ISS and TBP, but the stress shielding phenomenon and safety of implants in the TBP models were inferior to those in the MIAP and ISS fixation models. Meanwhile, MIAP and ISS fixation were more helpful to the healing processing than was TBP fixation, especially at the fracture interface of the second and third vertebral body levels.
Related Papers
- → Accidental Injury : Biomechanics and Prevention(1993)440 cited
- Basic biomechanics of the musculoskeletal system(2012)
- Biomechanics: Principles, Trends and Applications(2011)
- The Norm and Pathology in Spinal Biomechanics: Main Aspects of Studies*(2014)
- → OS19-4 Elastic Theory of Indentation Test of Biological Tissues and Approximate Solution(Orthopaedic Biomechanics,OS19 Biomechanics and its applications,BIOMECHANICS)(2015)