Solvent Hold Tank Sample Results for MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 AND MCU-13-148: Quarterly Sample from January 2013
2013
Citations Over Time
Abstract
Savannah River National Laboratory (SRNL) analyzed solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-13-143, MCU-13-144, MCU-13-145, MCU-13-146, MCU-13-147 and MCU-13-148 received 29 January 2012 are reported. The results show that the solvent at MCU does not require an Isopar® L addition, but it will require addition of trioctylamine. SRNL also analyzed the SHT sample for {sup 137}Cs content and determined the measured value is within tolerance and the value has returned to levels observed in 2012.