OBSERVATIONS OF VERTICAL AIR TEMPERATURE OF URBAN AND SUBURBAN AREA IN NAGANO CITY
Citations Over Time
Abstract
In order to research thermal environment in the heights of middle and high buildings, the observations of vertical air temperature were carried out at10 points in Nagano City for over one year. The authors obtained the following results;(1) In summer, high-rise air temperature are higher in daytime and lower in nighttime than that near the ground.(2) H-L (vertical difference of temperature) is larger in daytime than nighttime.(3) H-L in daytime is large on sunny days in early and high summer.(4) Sky view factor and H-L have a negative correlation in daytime. Therefore, in areas dense with buildings, difference between temperature near the ground and that high above the ground in daytime.Temperature in the heights of middle and high buildings differ from that near the ground, particularly in hot seasons and daytime.
Related Papers
- → Urban heat island analysis of Greater Manchester, UK using sky view factor analysis(2015)26 cited
- → Evaluating the Annual Effect of the Sky View Factor on the Indoor Thermal Environment of Residential Buildings by Envi-met(2022)7 cited
- → Rapid Estimation of Sky View Factor and Its Application to Human Environment(2004)11 cited
- → FIELD STUDY OF EFFECT OF STREET AND ITS TREES ON THERMAL ENVIRONMENT OF SIDEWALKS(1995)8 cited
- → SKY FACTOR OF STREET : TStudy on light environment Part2(1991)